Description
MECHANICAL DATA of the LMIX3-000-00,3-1-00 | ELGO Encoder, 0.3M Cable
Measuring principle | incremental |
Repeat accuracy | ± 1 increment |
System accuracy in µm at 20 °C | ± (25 + 20 x L), L= measuring length in meters |
Distance sensor / tape | max. 2.0 mm |
Sensor housing material | zinc die cast |
Housing dimensions (L x W x H) | 30 x 12.5 x 25 mm |
Required magnetic tape | MB20-50-10-1-R |
Pole pitch | 5 mm |
Max. measuring length | theoretically unlimited |
Connections | open cable ends |
Sensor cable | 1.5 m standard length, others on request, drag chain suitable |
Sensor cable bending radius | 60 mm |
Weight | approx. 35 g, each without cable, cable: approx. 60 g/m |
ELECTRICAL DATA
Power supply voltage | 10 … 30 VDC or 5 VDC |
Residual ripple | 10…30 VDC: <10 %, 5 VDC: ± 25 mV |
Current consumption | 10 … 30 VDC: max. 150 mA, 5 VDC: max. 200 mA |
Output signals | A, A’, B, B’, Z, Z’ |
Output levels | HTL or TTL |
Output current per channel | max. 20 mA |
Resolution (at 4 edge evaluation) | 0.025 mm |
Index pulse | every 5 mm (periodically), |
Max. output frequency per channel | 100 kHz |
Operating speed | 5 m/s |
Max. rotation speed | 300.000 U/min per number of pole pairs |
ENVIRONMENTAL CONDITIONS
Storage temperature | -25 … +85 °C |
Operating temperature | -10 … +70 °C, -25… +85 °C on request |
Humidity | 95 %, non-condensing |
Protection class | IP67 |